• LiNA MaxFlow™

    Powerful suction and irrigation system with electrosurgery applications.

    Safety

    LiNA MaxFlow

    • Suction probe with relieving eyes and false-air regulator on suction handle designed for procedures where delicate suction is required.

    LiNA MaxFlow Endohook

    • Monolar endohook with safety function for retraction of electrode tip into cannula. Designed for safe suction and irrigation when diathermy function is not in us.

    VERSATILE

    LiNA MaxFlow

    • Suction probe available in 5mm or 10mm, and 5mm extended length (370mm)•Choice of solely suction and irrigation function or supplement with accessory for monopolar or bipolar electrosurgical accessories available: LiNA MaxFlow Endohook and LiNA MaxFlow Blunt Coagulator

    LiNA MaxFlow Endohook

    • electrode tips on monopolar endohook designed for precise dissection, cutting and coagulation in a variety of surgical applications

    LiNA MaxFlow Blunt Coagulator
    Possibility of

    • coagulation with bipolar energy while at the same time using S/I
    • immediate reaction to sudden bleeding
    • minimize thermal spread due to instant cooling

    Functional

    LiNA MaxFlow

    •Unique separate channel design in handle designed to reduce risk of blood clots or debris blockage

    •True 9mm direct flow through whole suction system when using a 10mm probe during suction and irrigation procedure

    •No need for frequent change of instruments during surgical procedure as suction, irrigation, dissection, coagulation and cutting is all in one instrument!

  • LiNA McCartney Tube™

    Improving the outcome of Minimally Invasive Gynaecology

    The LiNA McCartney Tube offers you a unique single use device, sterile and ready to use.

  • LiNA OperåScope™

    Single-Use Operative Hysteroscopy System

    See and Treat Hysteroscopywithout capital cost or complexity.
    The complete system for see and treat hysteroscopy in the office setting.

     

    References:

    1. Bettocchi, S. Instrumentation in Office Hysteroscopy. In: LD Bradley and T Falcone, eds. Hysteroscopy. Office evaluation and management of the uterine cavity. Philadelphia: Mosby Elsevier; 2009: 3
    2. Salazar, Christina Alicia et al. Office Operative Hysteroscopy: An Update. Journal of Minimally Invasive Gynecology, Volume 25, Issue 2 , 199 – 208
    3. Franchini, Mario et al. Hysteroscopic Endometrial Polypectomy: Clinical and Economic Data in Decision Making. Journal of Minimally Invasive Gynecology , Volume 25 , Issue 3 , 418 – 425
    4. General Reprocessing Instructions for KARL STORZ Products (USA) PI-000035-20.1 2-03-11
    5. Sallam HN, Agameya AF, Rahman AF, et al. Ultrasound measurement of the uterocervical angle before embryo transfer: A prospective controlled study. Hum Reprod. 2002;17(7):1767–1772.
    6. Overcoming barriers to levonorgestrel-releasing intrauterine system placement: an evaluation of placement of LNG-IUS 8 using the modified EvoInserter®. Contraception, 96(6), 426-431.
    7. Bednarek, P. H., & Jensen, J. T. (2009). Safety, efficacy and patient acceptability of the contraceptive and non-contraceptive uses of the LNG-IUS. International Journal of Women’s Health, 1, 45–58
  • LiNA OrthoSuction™

    Orthopaedic Suction System with Filter

     

    For removal of debris and blood during orthopaedic surgery.

     

    LiNA OrthoSuction

    The LiNA OrthoSuction is designed to remove debris and blood during orthopaedic surgery. The built-in filter in the handle ensures a free flow throughout the suction system. The filter traps bone clips, bone cement, blood clots and other debris likely to cause blocking.

    LiNA OrthoSuction comes with a short and a long flexible suction tip. By reversing the tips you have a choice of four different positions for rapid evacuation of larger debris and fluids from areas such as the femoral shaft. The non-slip handle ensures safe handling during suction.

    The LiNA OrthoSuction is useful in any surgical procedure where suction of debris and blood is required. It is, however, designed particularly for hip, knee, and spinal surgery, aortic aneurysm and abdominal surgery.

    LiNA-OrthoSuction_High

  • LiNA Pencils™

    For open Monopolar
    Electrosurgical pencils

  • LiNA Port™

    Single use 5mm trocar system

    The LiNA Port is a single use trocar system fulfilling the demand for quality and efficiency at a competitive price.

    Safety

    • Silicone valve – airtight seal

    Ensuring minimum loss of pneumoperitoneum during surgery.

    • Dilating tip for delicate tissue

    The blunt dilating tip in the LiNA Port range supports non-traumatic entry.

    Functional

    • Threaded cannula

    To optimize efficient abdominal retention.

    Versatile

    • Choice of Dilating, Conical or Pyramidal tip

    Beside the dilating tip, the LiNA Port is available with conical or pyramidal tip for sharp and easy entry.

    • Two Lengths – Short and Long Ports

    Short 62mm and Long 84mm. Diameter inside cannula: Æ5,8mm allows easy insertion of all 5mm instruments. Suitable for laparoscopic procedures on most patients.

    • Gas Ports

    The cannulas are available with either a simple gas port, a gas port with on/off valve or without gas port.

    • Single Pack and Dual Pack

    The LiNA Port is available in Single pack and Dual pack. The Dual Pack includes one trocar, two cannulas and one LiNA Clear Sight Wipe AntiFog Solution for camera optics.

Showing 31–36 of 40 items