ByRL GYNAECOLOGY INSTRUMENTS

0 reviews Add a review
Categories: ,

ByRL Uterine Manipulator

The fully visualization of the uterus and the adnexa is the important basis for a good gynecological laparoscopic surgery. An Uterine Manipulator that can be adjusted to different angles allows the operator to flex and rotate the uterus so that it can be brought into an optimal position.

Uterine Manipulator are available in 2 types :

  1. Uterine Manipulator “Marwah” type
  2. Uterine Manipulator “Sukhadia” type

Product Features :

  • Made up of Medical Grade plastic / polycarbonate and Stainless steel.
  • Fully reusable

Description

Marwah Type

Sukhadia Type

Ordering Information

REF No. Description Size Packing
BUTM-S-10 ByRL Uterine Manupulator ,10mm, Marwah Type 10mm Box of 1
BUTM-M-10 ByRL Uterine Manupulator ,10mm, Sukhadiya Type 10mm Box of 1

ByRL Myoma Screw 

A myoma is a benign (non-cancerous) tumour in the muscle of the uterus. This myoma screw is used in surgery to remove such fibroids. It can be done abdominally or vaginally. The fibroid is ‘screwed’ and clamped before removal. The myoma screw is almost crude in its simplicity. It has a straight shaft with an handle and a corkscrew head.

Product Features:

  • Made up of Medical Grade Stainless Steel 304.
  • Sharp corkscrew head for fast and easy penetration in the fibroid.
  • Reusable / Autoclavable Plastic / Polycarbonate Handle.
  • Available in 5mm and 10mm diameter with 30cm length.

Ordering Information

REF No. Description Size Packing
BMS-05 ByRL Myoma Screw 5mm, 30cm Long 5mm Box of 1
BMS-10 ByRL Myoma Screw 10mm, 30cm Long 10mm Box of 1

ByRL Laparoscopic PCOD Needle

Laparoscopic PCOD Needle is used to perform Laparoscopic ovarian drilling using an insulated needle used with monopolar current, to remove ovarian cyst. Laparoscopic PCOD Needle uses electrosurgical needle punctures the ovary 4 to 10 times.

Product Features:

  • Insulated needle shaft with teflon to tolerate high monopolar electrosurgical energy.
  • Reusable / Autoclavable Plastic / Polycarbonate Handle.
  • Standard monopolar connector pin for unipolar coagulation, can be fit in with any standard monopolar cable
  • Available in 5mm diameter with 33cm length.

Ordering Information

REF No. Description Size Packing
BPCODN-05 ByRL PCOD Needle, 5mm, 33cm Long 5mm Box of 1

ByRL Ring Applicator

This simple mechanical technique is the natural choice for safe, uncomplicated female sterilization. The Silastic ring is an inert, radio opaque silicone band that is simply applied to a looped section of the fallopian tube with Ring Applicator. During Tubal ligation,the Ring Applicator contains forceps to grasp the fellopian tube 3cm to 4cm from the corneal segment of the fallopian tube is drawn inside a narrow cone shaped applicator. Once the silastic ring contracts, the fallopian tube is blocked. Deprived of blood supply, the constricted loop is replaced with scar tissue and the remaining healthy tubal segments separate.

Product Features:

  • Made up of Medical Grade stainless steel 304.
  • Contains 2 cone shaped loader applicator with 1 pusher.
  • Reusable/ Autoclavable Plastic/ Polycarbonate ring type handle for better grip.
  • Available in 5mm & 10mm with 30cm length.

Ordering Information

REF No. Description Size Packing
BRAPL-05 ByRL Ring Applicator with Pusher & Loader, 5mm, 30cm Long 5mm Box of 1

ByRL Colpotomy Tube

Several gynecologic surgery protocols require a colpotomy as part of the overall surgical procedure. It is performed whenever the surgeon needs to access the vagina. Several of these surgeries include:

  • Tubal sterilization : Sterilization is a procedure that can be performed using either abdominal or vaginal procedures. When a vaginal procedure is selected by the surgeon, he performs a colpotomy and may also insert a culdoscope to locate the tubes (culdoscopy), and close them off.
  • Removal of myomas : Myomas are fibroid tumors of the muscle tissue of the uterus and they are sometimes removed vaginally by colpotomy.
  • Removal of pelvic cysts and masses : In one treatment variant, patients may undergo a laparoscopy followed by a colpotomy for the vaginal extraction of the pelvic cyst or mass.
  • Hysterectomy One technique used to surgically remove the uterus combines three steps, an initial laparoscopic stage, followed by a vaginal stage, and a final laparoscopic stage. The colpotomy is performed during the second step to deliver the uterus into the vagina.
  • Dysmenorrhea : Separation of the uterosacral ligaments via colpotomy is an approach that has been used for the relief of dysmenorrhea (painful menstruation).
  • Complications in pregnancy and childbirth : Colpotomy may be used in the management of difficult pregnancies and childbirths.

During LAVH / Vaginal Hysterectomy,The soft curvature of Colpotomy tube acts as a safe guide during sectioning of the uterus and ensures no trauma to the tissue, whilst the airtight valves prevent loss of pneumoperitoneum after colpotomy. The Tube can also be used as a conduit for removing specimen during surgery.

Product Features:

  • Made up of Medical grade Plastic and silicon.
  • The distal end is made up of soft silicon ensures minimal tissue trauma.
  • Airtight Valves prevent loss of Pneumoperitoneum.
  • Available in 32mm / 38mm diameter with 20cm length.
  • Fully reusable.

Ordering Information

REF No. Description Size Packing
BCT-20 ByRL Colpotomy Tube, 32mm/38mm, 20cm Long 32mm/38mm Box of 1

Reviews

There are no reviews yet.

Be the first to review “ByRL GYNAECOLOGY INSTRUMENTS”

Your email address will not be published. Required fields are marked *