LiNA LapGuard™
Laparoscopic Smoke Filtration System
Safe
functional
LiNA LapGuard Smoke Filtration System
Safety
Clean air in the operating room
Several studies confirm that electrosurgical smoke affects the health of both staff and patients and reports indicate that headache, nausea and upper respiratory irritation are amongst the most common issues[1].
The smoke consists of carbonized tissue, blood, viral particles, DNA, bacteria, carbon dioxide, toxic gases and water and these airborne particles are small enough to penetrate deep into the respiratory tract[2].
As standard surgical masks cannot effectively filter these particles, smoke evacuation has become a topic of immediate importance. National nurse associations and authorities including AORN and NIOSH recommend that smoke should be removed using smoke evacuators [3, 4]. In addition, during laparoscopic surgery, surgical smoke will impair visibility in the peritoneum. Hence smoke should be evacuated and filtered[5].- Surgical smoke-a review of the literature” – Barrett WL, Garber SM- Business Briefing: Global Surgery. 2004;1-7.
- “Electrosurgery smoke: hazards and protection” – O’Grady KF; Easty AC;Toronto Hospital, Ontario, Canada – J Clin Eng. 1996 Mar-Apr;21(2):149-55.
- Hazard control 11 (HC11)” – NIOSH – Publication no. 96-128 – September 1996.
- “AORN Position Statement – Statement on Surgical Smoke and Bio-Aerosols”, approved by House of Delegates, Anaheim, CA. April 2008.
- Surgical Smoke – A concern for infection control practitioners” – Girolamo A. Ortolano, Joseph S. Cervia, Francis P. Canonica – Managing Infection Control, August 2009 (k8-54)
Functionality
Remove smoke and odors
With ULPA filter with active carbon, LiNA LapGuard offers evacuation and filtration of electrosurgical smoke during laparoscopic procedures. By using LiNA LapGuard the patient’s and staff’s exposure to potentially harmful smoke is minimised
Improved visibility
A better view of the surgical site is secured resulting in a more efficient procedure.
Easy to use
Attach the luer lock connector to a trocar system with gasport. During extensive use of electrosurgery the roller clamp may be adjusted to allow for a constant gas flow.
LiNA Librata™
Cordless Balloon Ablation Device(Endometrial Ablation Simplified)
2 minute treatment time with the versatility of balloon therapy.
A fully automated, portable solution for endometrial ablation.Quick
- ~2 minute thermal treatment time.
- No complicated setup.
Simple
- Slim 5.4 mm catheter requires minimal or no dilation.
- Ideally suited for ambulatory gynecology.
- Only a simple sounding measurement required.
Cordless Intelligence
- No cables. No generator. No capital investment.
- Intelligent software automatically manages time, temperature, and pressure.
LiNA MaxFlow™
Powerful suction and irrigation system with electrosurgery applications.
Safety
LiNA MaxFlow
- Suction probe with relieving eyes and false-air regulator on suction handle designed for procedures where delicate suction is required.
LiNA MaxFlow Endohook
- Monolar endohook with safety function for retraction of electrode tip into cannula. Designed for safe suction and irrigation when diathermy function is not in us.
VERSATILE
LiNA MaxFlow
- Suction probe available in 5mm or 10mm, and 5mm extended length (370mm)•Choice of solely suction and irrigation function or supplement with accessory for monopolar or bipolar electrosurgical accessories available: LiNA MaxFlow Endohook and LiNA MaxFlow Blunt Coagulator
LiNA MaxFlow Endohook
- electrode tips on monopolar endohook designed for precise dissection, cutting and coagulation in a variety of surgical applications
LiNA MaxFlow Blunt Coagulator
Possibility of- coagulation with bipolar energy while at the same time using S/I
- immediate reaction to sudden bleeding
- minimize thermal spread due to instant cooling
Functional
LiNA MaxFlow
•Unique separate channel design in handle designed to reduce risk of blood clots or debris blockage
•True 9mm direct flow through whole suction system when using a 10mm probe during suction and irrigation procedure
•No need for frequent change of instruments during surgical procedure as suction, irrigation, dissection, coagulation and cutting is all in one instrument!
LiNA McCartney Tube™
Improving the outcome of Minimally Invasive Gynaecology
The LiNA McCartney Tube offers you a unique single use device, sterile and ready to use.
LiNA OperåScope™
Single-Use Operative Hysteroscopy System
See and Treat Hysteroscopywithout capital cost or complexity.
The complete system for see and treat hysteroscopy in the office setting.References:
- Bettocchi, S. Instrumentation in Office Hysteroscopy. In: LD Bradley and T Falcone, eds. Hysteroscopy. Office evaluation and management of the uterine cavity. Philadelphia: Mosby Elsevier; 2009: 3
- Salazar, Christina Alicia et al. Office Operative Hysteroscopy: An Update. Journal of Minimally Invasive Gynecology, Volume 25, Issue 2 , 199 – 208
- Franchini, Mario et al. Hysteroscopic Endometrial Polypectomy: Clinical and Economic Data in Decision Making. Journal of Minimally Invasive Gynecology , Volume 25 , Issue 3 , 418 – 425
- General Reprocessing Instructions for KARL STORZ Products (USA) PI-000035-20.1 2-03-11
- Sallam HN, Agameya AF, Rahman AF, et al. Ultrasound measurement of the uterocervical angle before embryo transfer: A prospective controlled study. Hum Reprod. 2002;17(7):1767–1772.
- Overcoming barriers to levonorgestrel-releasing intrauterine system placement: an evaluation of placement of LNG-IUS 8 using the modified EvoInserter®. Contraception, 96(6), 426-431.
- Bednarek, P. H., & Jensen, J. T. (2009). Safety, efficacy and patient acceptability of the contraceptive and non-contraceptive uses of the LNG-IUS. International Journal of Women’s Health, 1, 45–58
LiNA OrthoSuction™
Orthopaedic Suction System with Filter
For removal of debris and blood during orthopaedic surgery.
LiNA OrthoSuction
The LiNA OrthoSuction is designed to remove debris and blood during orthopaedic surgery. The built-in filter in the handle ensures a free flow throughout the suction system. The filter traps bone clips, bone cement, blood clots and other debris likely to cause blocking.
LiNA OrthoSuction comes with a short and a long flexible suction tip. By reversing the tips you have a choice of four different positions for rapid evacuation of larger debris and fluids from areas such as the femoral shaft. The non-slip handle ensures safe handling during suction.
The LiNA OrthoSuction is useful in any surgical procedure where suction of debris and blood is required. It is, however, designed particularly for hip, knee, and spinal surgery, aortic aneurysm and abdominal surgery.
LiNA Port™
Single use 5mm trocar system
The LiNA Port is a single use trocar system fulfilling the demand for quality and efficiency at a competitive price.
Safety
• Silicone valve – airtight seal
Ensuring minimum loss of pneumoperitoneum during surgery.
• Dilating tip for delicate tissue
The blunt dilating tip in the LiNA Port range supports non-traumatic entry.
Functional
• Threaded cannula
To optimize efficient abdominal retention.
Versatile
• Choice of Dilating, Conical or Pyramidal tip
Beside the dilating tip, the LiNA Port is available with conical or pyramidal tip for sharp and easy entry.
• Two Lengths – Short and Long Ports
Short 62mm and Long 84mm. Diameter inside cannula: Æ5,8mm allows easy insertion of all 5mm instruments. Suitable for laparoscopic procedures on most patients.
• Gas Ports
The cannulas are available with either a simple gas port, a gas port with on/off valve or without gas port.
• Single Pack and Dual Pack
The LiNA Port is available in Single pack and Dual pack. The Dual Pack includes one trocar, two cannulas and one LiNA Clear Sight Wipe AntiFog Solution for camera optics.
LiNA Powerblade™
Single use multifunctional forceps for bipolar coagulation and cutting
Functional
Minimize procedure time
A clean and precise cut every time
- The bipolar electrode/blade never goes dull
- The patented design allows for bipolar transection of the tissue. Cutting is achieved through bipolar energy, not mechanical action of a knife blade
- For use with all standard bipolar electrosurgical units
- Broad range of size, length and jaw geometry
Versatile
LiNA PowerBlade can be used together with all standard bipolar electrosurgical units. No capital equipment investment is required to use the LiNA PowerBlade
- Wide range of functions
LiNA PowerBlade is a bipolar coagulating and cutting forceps for improved techniques in laparoscopic procedures. As an all in one instrument, the LiNA PowerBlade is ideal for many complex and time consuming procedures
- Grasping Coagulating
- Dissecting Cutting
Safe
Unique bipolar power blade cutting function
- Advancing the cutting electrode for transection, the bipolar current is automatically switched from the jaws
- Electro surgical current passes through the tissue between the cutting electrode/blade and the jaws
- Bipolar electro surgical cut with coagulation along surface of cutting electrode/blade ensures a reduction in bleeding compared to a conventional knife blade instrument
LiNA SeaStar™
and LiNA Skin HookTM
Retractor ring and skin hook
Complete system for retracting soft tissue from the operative surface
The LiNA SeaStar and LiNA Skin Hook is a complete system for retracting both delicate and solid tissue. The flexible design of the system allows easy adjustment and repositioning of the LiNA SeaStar during the surgical procedures and provides optimal exposure of the surgical site.
Safe
Self-retaining
The LiNA SeaStar and LiNA Skin Hook is a self-retaining system freeing the hands of the surgeon and the surgical assistant to handle other tasks in the OR.
Functional
Broad range of LiNA SeaStar retractor rings
• LiNA SeaStar
The LiNA SeaStar is provided in a broad range of shapes and sizes which can easily be adjusted to fit various anatomical areas, thereby facilitating different surgical applications e.g. vaginal and rectal surgery.
• LiNA Skin Hook
By securing the LiNA Skin Hook on to the LiNA SeaStar the exposure of the incision is increased. The flexible and elastic hook can be adjusted during the procedure to create optimum tension. The LiNA Skin Hook is available with 3 different stainless steel hooks.
LiNA Surgipen™
Reusable finger-controlled Electrosurgical
pencil for open monopolar electrosurgery
safe
versatile
functional
LiNA Surgipen
The slim lightweight design makes it easy and comfortable for the surgeon to use during long procedures. A soft and flexible silicone cable ensures easy handling and long durability. The silicone cable remains soft even after many autoclavings.
Press Button switches with “click”
Sealed waterproof switches ensure durability and safety in the operating theatre. The switches’ homogenous activation pressure provides very high comfort and reduced movement of the pencil when activated
Versatile Product Range
A wide range of possible combinations in connectors, adaptors, cable lenghts and electrodes makes it possible to meet all operating theatre demands. The LiNA Surgipen can be used for all major elec-trosurgical units either with the 3-pin connector, ICC connector or by using adaptor
LiNA Xcise™
The LiNA XciseTM is a cordless fully disposable morcellator intended for tissue morcellation during laparoscopic gynaecological procedures. The unique design of the LiNA XciseTM provides safe and easy control during hysterectomy and myomectomy.
Simplicity
Single use device that is completely ready to use
• Cordless and no assembly required
The morcellator can be used right out of the box and as it is cordless there is no need for assembly to driver box or cable. The LiNA Xcise™ is therefore quick, simple and easy to use and facilitates unlimited mobility of the OR staff.
• Fully disposable
The LiNA Xcise™ is RoSH compliant and fully disposable in regular hospital waste.
• Power
The LiNA Xcise™ has a higher torque and runs at 1,000RPM to morcellate through the most fibrotic tissue (Largest reported uterus morcellated by LiNA Xcise was 2930gr).
Innovation in Gynaecology
Cordless Morcellator
Improved Safety
Reducing procedure time
Showing 29–40 of 40 items